abb調(diao)速(su)器(qi)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu),ABB維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)中心(xin),DCS800直(zhi)流調(diao)速(su)器(qi)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu),DCS600直(zhi)流調(diao)速(su)器(qi)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)中心(xin),DCS500系列控(kong)制(zhi)器(qi)壞維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu),ABB直(zhi)流調(diao)速(su)器(qi)DCS400維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu),,你(ni)的(de)選擇沒有(you)錯。公司自成(cheng)立以(yi)來,長期維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)變頻器(qi)及伺服驅動器(qi)的(de),觸摸屏,PLC,直(zhi)流調(diao)速(su)器(qi)等(deng),積累(lei)了(le)豐富的(de)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)經驗,對所(suo)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)的(de)機器(qi)建立完(wan)善(shan)的(de)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)檔案(an),所(suo)有(you)我(wo)們(men)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)的(de)機器(qi)我(wo)們(men)都有(you)完(wan)善(shan)的(de)參數備(bei)份,確(que)保我(wo)們(men)維(wei)(wei)(wei)(wei)修(xiu)(xiu)(xiu)(xiu)的(de)機器(qi)上(shang)機即能使用
abb調速器維修,ABB直流(liu)控(kong)制器維(wei)(wei)修,ABB直流(liu)驅動器/變頻器維(wei)(wei)修,公司擁(yong)有*、*的檢(jian)測儀(yi)器及專業維(wei)(wei)修技師(shi),如示波器、邏輯分(fen)析(xi)儀(yi)、集成電路在(zai)線測試儀(yi)、負(fu)載試驗裝備等(deng),實(shi)現無圖紙化芯片級維(wei)(wei)修,修復率達95%以上。
abb調速器維修,故障分析:lkz789dhABBDCS501直流調速器維修變頻器分為 1 交---交型 輸入是交流,輸出也是交流將工頻交流電直接轉換成頻率、電壓均可控制的交流,又稱 直接式變頻器2 交—直---交型 輸入是交流,變成直流再變成交流輸出將工頻交流電通過整流變成直流電,然后再把直流電變成頻率、電壓、均可控的交流電又稱為間接變頻器。多數情況都是交直交型的變頻器。故判斷X軸發生低頻振蕩。發生振蕩的原因有: 軸位置環增益不合適。 機械部分間隙大
2變(bian)(bian)頻器的組成(cheng)由主電(dian)(dian)(dian)(dian)路(lu)和控制電(dian)(dian)(dian)(dian)路(lu)組成(cheng)主電(dian)(dian)(dian)(dian)路(lu) 由整(zheng)流(liu)(liu)器 中(zhong)間直(zhi)流(liu)(liu)環節 逆變(bian)(bian)器 組成(cheng)先(xian)看主電(dian)(dian)(dian)(dian)路(lu)原(yuan)理圖三相工頻交流(liu)(liu)電(dian)(dian)(dian)(dian) 經(jing)過(guo)VD1 ~ VD6 整(zheng)流(liu)(liu)后(hou),正(zheng)極送入到(dao)緩(huan)沖(chong)電(dian)(dian)(dian)(dian)阻(zu)RL中(zhong),RL的作(zuo)用是防止電(dian)(dian)(dian)(dian)流(liu)(liu)忽然(ran)變(bian)(bian)大(da)。經(jing)過(guo)一段時間電(dian)(dian)(dian)(dian)流(liu)(liu)趨于穩定后(hou),晶閘管(guan)或繼電(dian)(dian)(dian)(dian)器的觸點會導(dao)通短路(lu)掉緩(huan)沖(chong)電(dian)(dian)(dian)(dian)阻(zu)RL ,這(zhe)(zhe)時的直(zhi)流(liu)(liu)電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)加在了(le)(le)濾波電(dian)(dian)(dian)(dian)容CF1、CF2 上,這(zhe)(zhe)兩(liang)(liang)個(ge)(ge)電(dian)(dian)(dian)(dian)容可(ke)以(yi)把(ba)脈動的直(zhi)流(liu)(liu)電(dian)(dian)(dian)(dian)波形變(bian)(bian)得平滑(hua)一些。由于一個(ge)(ge)電(dian)(dian)(dian)(dian)容的耐壓(ya)(ya)(ya)有限,所以(yi)把(ba)兩(liang)(liang)個(ge)(ge)電(dian)(dian)(dian)(dian)容串起來用,耐壓(ya)(ya)(ya)就(jiu)提高了(le)(le)一倍。又因為(wei)兩(liang)(liang)個(ge)(ge)電(dian)(dian)(dian)(dian)容的容量不一樣(yang)的話,分壓(ya)(ya)(ya)會不同,所以(yi)給兩(liang)(liang)個(ge)(ge)電(dian)(dian)(dian)(dian)容分別并聯(lian)了(le)(le)一個(ge)(ge)均壓(ya)(ya)(ya)電(dian)(dian)(dian)(dian)阻(zu)R1、R2 ,這(zhe)(zhe)樣(yang),CF1 和CF2 上的電(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)就(jiu)一樣(yang)了(le)(le)。
特(te)別是(shi)使用(yong)一(yi)(yi)定的(de)年限以(yi)后,f12一(yi)(yi)般都是(shi)勵磁通路的(de)故(gu)障(zhang)(zhang)(zhang)。F9/F10報警,主要是(shi)檢(jian)(jian)測(ce)電(dian)路出(chu)了(le)故(gu)障(zhang)(zhang)(zhang)。出(chu)現(xian)故(gu)障(zhang)(zhang)(zhang)的(de)同時,還沒啟(qi)動,面板上就檢(jian)(jian)測(ce)到(dao)不正(zheng)確(que)的(de)讀(du)數。F16/F18一(yi)(yi)般都是(shi)測(ce)速反饋的(de)問題。如果(guo)沒用(yong)測(ce)速反饋(如測(ce)速發(fa)電(dian)機檢(jian)(jian)測(ce)或編碼器檢(jian)(jian)測(ce)),就是(shi)電(dian)樞電(dian)壓發(fa)聵檢(jian)(jian)測(ce)電(dian)路出(chu)了(le)故(gu)障(zhang)(zhang)(zhang)。
abbdcs直流調速器常見報警故障有:
F12 Field Undercurrent 勵磁磁場欠流
F9 Mains Undervoltage 供電電源欠壓
F 10 Mains Overvoltage 供電電源過壓
F16 Speed Meas Fault 測速故障
F18 Overspeed 電機(ji)超(chao)速
ABB的整(zheng)流器主(zhu)電(dian)(dian)(dian)源(yuan)是不容易(yi)出問(wen)題的,只要(yao)接觸器吸合了,三(san)相(xiang)電(dian)(dian)(dian)源(yuan)電(dian)(dian)(dian)壓(ya)正常,就不應(ying)當(dang)(dang)報(bao)主(zhu)電(dian)(dian)(dian)源(yuan)欠壓(ya)。然而事實并沒有這么簡單,這要(yao)從(cong)它(ta)的電(dian)(dian)(dian)壓(ya)檢測電(dian)(dian)(dian)路(lu)(lu)說起。三(san)相(xiang)主(zhu)線路(lu)(lu)經過銅排(pai)供給可控硅后(hou),還有三(san)根小線借到(dao)電(dian)(dian)(dian)源(yuan)板上(shang),經過保險后(hou)供給勵磁整(zheng)流電(dian)(dian)(dian)路(lu)(lu),電(dian)(dian)(dian)壓(ya)檢測電(dian)(dian)(dian)路(lu)(lu)也是從(cong)保險后(hou)取樣(yang)的,也就是說取樣(yang)電(dian)(dian)(dian)路(lu)(lu)、檢測元件(jian)以(yi)及勵磁短路(lu)(lu)引起的保險融斷都能引發F9故(gu)障(zhang),所以(yi)當(dang)(dang)出現這個故(gu)障(zhang)的時候,我們不能僅僅從(cong)電(dian)(dian)(dian)壓(ya)入手(shou),不然很難找到(dao)真正的故(gu)障(zhang)點。
ABB DCS800直流調速器維修型號
DCS800-S01-0020-04 DCS800-S01-0045-04 DCS800-S01-0065-04 DCS800-S01-0090-04
DCS800-S01-0125-04 DCS800-S01-0180-04 DCS800-S01-0230-04 DCS800-S01-0315-04
DCS800-S01-0405-04 DCS800-S01-0470-04 DCS800-S01-0610-04 DCS800-S01-0740-04
DCS800-S01-0900-04 DCS800-S01-1200-04 DCS800-S01-1500-04 DCS800-S01-2000-04
DCS800-S02-0025-04 DCS800-S02-0050-04 DCS800-S02-0075-04 DCS800-S02-0100-04
ABB DCS600直流調速器維修型號
DCS60x-0025-41/51、DCS60x-0050-41/51、DCS60x-0075-41/51、DCS60x-0100-41/51
DCS601-0140-41/51、DCS602-0140-41/51、DCS601-0200-41/51、DCS602-0200-41/51
DCS601-0250-41/51、DCS602-0250-41/51、DCS601-0350-41/51、DCS602-0350-41/51
DCS601-0450-41/51、DCS602-0450-41/51、DCS601-0520-41/51、DCS602-0520-41/51
DCS601-0680-41/51、DCS602-0680-41/51、DCS601-0820-41/51、DCS602-0820-41/51
DCS601-1000-41/51、DCS602-1000-41/51、DCS60x-1203-41/51、DCS60x-1503-41/51
DCS60x-2003-41/51、DCS60x-2500-41/51、DCS60x-3300-41/51、DCS60x-4000-41/51
上海恒稅電氣有限公司 版權所有 ICP備:GoogleSitemap 技術支持: