西門子直流調速裝置上電就跳閘-二小時好;SIEMENS維(wei)(wei)(wei)修廠家,上海(hai)恒稅電氣有限(xian)公(gong)司(si),你的(de)(de)選擇沒有錯。公(gong)司(si)自成立以來,長(chang)期銷售維(wei)(wei)(wei)修西門子變頻器及伺服驅動器的(de)(de),觸摸(mo)屏,PLC,直流調速器等,積累(lei)了豐富的(de)(de)維(wei)(wei)(wei)修經驗(yan),對所維(wei)(wei)(wei)修的(de)(de)機(ji)(ji)器建立完善(shan)的(de)(de)維(wei)(wei)(wei)修檔案,所有我們維(wei)(wei)(wei)修的(de)(de)機(ji)(ji)器我們都有完善(shan)的(de)(de)參數備份(fen),確保我們維(wei)(wei)(wei)修的(de)(de)機(ji)(ji)器上機(ji)(ji)即能使用。
西門子直流調速裝置上電就跳閘-二小時好;
維(wei)修(xiu)起來可(ke)就沒(mei)那(nei)么順(shun)利了。先是(shi)維(wei)修(xiu)開關電(dian)(dian)(dian)源,主(zhu)(zhu)要元件無一(yi)幸免(mian),通電(dian)(dian)(dian)試機后(hou)發(fa)(fa)(fa)(fa)現(xian)檢測比較器(qi)全部冒(mao)煙,更換(huan)后(hou)測量(liang)+24V,+15V,-15V,+5V均(jun)已修(xiu)復,接(jie)主(zhu)(zhu)板(ban)后(hou)顯(xian)示(shi)(shi)(shi)屏不(bu)(bu)亮,面板(ban)指示(shi)(shi)(shi)燈(deng)長亮,測量(liang)主(zhu)(zhu)板(ban)電(dian)(dian)(dian)壓正(zheng)常(chang),CPU嚴重(zhong)發(fa)(fa)(fa)(fa)熱,只好更換(huan)主(zhu)(zhu)板(ban)。更換(huan)主(zhu)(zhu)板(ban)后(hou)接(jie)通220V工作電(dian)(dian)(dian)源,顯(xian)示(shi)(shi)(shi)CALIBRATION FAIL校準失敗,然后(hou)約半分(fen)鐘后(hou)觸(chu)發(fa)(fa)(fa)(fa)板(ban)100歐電(dian)(dian)(dian)阻冒(mao)煙,正(zheng)常(chang)情(qing)況下直流調速器(qi)這個(ge)(ge)(ge)時候(hou)應(ying)該要顯(xian)示(shi)(shi)(shi)正(zheng)常(chang),不(bu)(bu)發(fa)(fa)(fa)(fa)熱不(bu)(bu)報警的, 清理線路后(hou)結(jie)果如下,主(zhu)(zhu)板(ban)觸(chu)發(fa)(fa)(fa)(fa)芯片2003輸出(chu)導(dao)(dao)通信(xin)號,經過電(dian)(dian)(dian)源板(ban)的十二(er)顆標記053的三極(ji)管(NPN,基極(ji)觸(chu)發(fa)(fa)(fa)(fa)后(hou)將集(ji)電(dian)(dian)(dian)極(ji)對(dui)地(di),集(ji)電(dian)(dian)(dian)極(ji)接(jie)的是(shi)脈(mo)(mo)沖(chong)變(bian)壓器(qi)的一(yi)個(ge)(ge)(ge)引(yin)腳(jiao)(jiao),另(ling)一(yi)個(ge)(ge)(ge)引(yin)腳(jiao)(jiao)通過100歐電(dian)(dian)(dian)阻接(jie)通24伏),放大導(dao)(dao)通脈(mo)(mo)沖(chong)變(bian)壓器(qi),跟功放輸出(chu)繼電(dian)(dian)(dian)器(qi)一(yi)個(ge)(ge)(ge)控制(zhi)方式。可(ke)逆(ni)式電(dian)(dian)(dian)源板(ban)插座排(pai)列:兩端(duan)共(gong)8個(ge)(ge)(ge)引(yin)腳(jiao)(jiao)是(shi)+24V,中間兩排(pai)共(gong)12個(ge)(ge)(ge)引(yin)腳(jiao)(jiao)為(wei)觸(chu)發(fa)(fa)(fa)(fa)脈(mo)(mo)沖(chong),不(bu)(bu)可(ke)逆(ni)小插座:右側4個(ge)(ge)(ge)引(yin)腳(jiao)(jiao)為(wei)+24V,左側6個(ge)(ge)(ge)引(yin)腳(jiao)(jiao)為(wei)脈(mo)(mo)沖(chong)。發(fa)(fa)(fa)(fa)熱冒(mao)煙的原因是(shi)其中一(yi)跟三極(ji)管短路,相當(dang)開脈(mo)(mo)沖(chong)變(bian)壓器(qi)初(chu)級得到了24V直流電(dian)(dian)(dian)壓,所以(yi)限流電(dian)(dian)(dian)阻會過熱冒(mao)煙。
將(jiang)三(san)(san)(san)極管(guan)更換后試機,顯示器(qi)報(bao)警ACCTS 故障(ACCTS FAILED),故障報(bao)警意(yi)思為電(dian)(dian)(dian)流傳(chuan)感(gan)器(qi)異(yi)常,但是此時三(san)(san)(san)個電(dian)(dian)(dian)流傳(chuan)感(gan)器(qi)都已經接好,線路(lu)也沒有開(kai)路(lu),三(san)(san)(san)個電(dian)(dian)(dian)流傳(chuan)感(gan)器(qi)有三(san)(san)(san)個引腳(jiao)(jiao)相連,另外三(san)(san)(san)個引腳(jiao)(jiao)送到藍色主(zhu)板插頭旁邊的六只(zhi)二極管(guan)形(xing)成三(san)(san)(san)相橋式整流,通過LM324比(bi)較(jiao)檢測。更換LM324后ACCTS FAILED故障消失。開(kai)關變壓器(qi)上邊三(san)(san)(san)個指示燈(deng):FLD HS OT ,ARM HS OT ,PHASE LOSS,分(fen)別是勵磁超(chao)溫(wen),電(dian)(dian)(dian)樞超(chao)溫(wen),三(san)(san)(san)相電(dian)(dian)(dian)平低(di)報(bao)警。當(dang)兩(liang)個溫(wen)度(du)燈(deng)異(yi)常點亮時測試方(fang)法(fa):溫(wen)度(du)線插頭外的兩(liang)顆圓形(xing)貼片電(dian)(dian)(dian)阻(zu)100歐兩(liang)端分(fen)別對地,1001(1K)方(fang)形(xing)貼片電(dian)(dian)(dian)阻(zu)為檢測腳(jiao)(jiao),此時如果兩(liang)個溫(wen)度(du)燈(deng)還(huan)異(yi)常亮起,說明檢測電(dian)(dian)(dian)路(lu)壞了。
西門子直流調速裝置上電就跳閘-二小時好;西門子6RA70直流(liu)調速器的弱磁設置完事方法。
1 . 系統設定值復位及偏(pian)差(cha)調整
?? 用PMU 執(zhi)行(xing)功(gong)能P051= 21,或在PC 中調用缺省的工廠設置參數構成基(ji)本
參數文件,凡是下文中未提到的參數都利(li)用缺省參數,參數值見手(shou)冊,用
P052=0 顯示那些與初始工廠設置不同的參數。
?? 合上裝置控制(zhi)電源(yuan)和操作(zuo)控制(zhi)電源(yuan)執行P051=21,偏差調整(P051=22)同(tong)時
進行,參數P825.02 被設置(zhi)。
2 . 整 流 裝 置 參 數 設 定
?? P067=1-5 選擇負(fu)載過負(fu)荷周期,見(jian)手冊,當本參數(shu)大于1 時,整流器額定
2
直流(liu)電(dian)流(liu)R072.01 將變為(wei)(wei)所選周期內的基本負載值,P075 參數(shu)必須(xu)設定(ding)為(wei)(wei)
1 或2。一般情況(kuang)下(xia),裝(zhuang)置的(de)計算的(de)晶閘(zha)管(guan)溫升包(bao)容上述過載周期
?? P075=0 不允許(xu)裝置(zhi)過載(zai), 裝置(zhi)最大輸出電流被(bei)限制在額定直流電流
R072.01
?? =1 電樞電流(liu)最大值(zhi)被(bei)限制在P077*1.8*整流(liu)器額(e)定直流(liu)電流(liu)R072.01,當計(ji)
算的(de)晶閘管溫升超(chao)過(guo)允許(xu)值(zhi)時(shi),報警A039 激活,電(dian)樞(shu)電(dian)流給定自動自動減
小到(dao)整流器額定電流R072.01。
?? =2 整流(liu)(liu)(liu)器電樞電流(liu)(liu)(liu)最大值被限制在 P077*1.8* 整流(liu)(liu)(liu)器額(e)定直(zhi)流(liu)(liu)(liu)電流(liu)(liu)(liu)
R072.01,當(dang)計算的晶閘管(guan)溫升超過允許值時,故障F039 被激(ji)活。
?? 本參數根據(ju)電機額定(ding)參數值和使用工況,從保護裝置過(guo)載的角度出發進(jin)行設
置,本參(can)數與P067 共(gong)同作用,對(dui)裝(zhuang)置的過負(fu)荷周期進行(xing)設定。
?? P078.01= 630V 主回(hui)路進線(xian)交(jiao)流電壓,作為判斷電壓故(gu)障的基(ji)準值
?? P078.02= 380V,勵磁進線電壓(ya)
?? 作為欠壓或過壓的判斷門檻(jian)電(dian)壓,相關參數(shu)見P351,P352,P361-P364.
3 . 電機參數(shu)設定
?? P100(F)= 額定電(dian)動機(ji)電(dian)樞電(dian)流(A)
?? P101(F)=額定電動機電樞電壓(V)
?? P102(F)= 額定電動機(ji)勵磁(ci)電流(A)
?? P103(F)=最(zui)小電機(ji)勵(li)磁電流(A),必須小于 P102 的(de)50%.在弱磁調速場合(he),一(yi)
般設(she)定(ding)到防止失磁的(de)數(shu)值.